What was found
PIT - DURING Q-4 CHECK, FOUND 1 INCH BY 6 INCH CORROSION IN FLOOR SUPPORT JUST INBOARD OF SEAT TRACK 19 AT STATION 200-237, CORROSION LEVEL 1. FABRICATED NEW FLOOR SUPPORT FROM EXTRUSION AND INSTALLED SAME PER SRM 53-11-1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-4 CHECK, FOUND 1 INCH BY 6 INCH CORROSION IN FLOOR SUPPORT JUST INBOARD OF SEAT TRACK 19 AT STATION 200-237, CORROSION LEVEL 1. FABRICATED NEW FLOOR SUPPORT FROM EXTRUSION AND INSTALLED SAME PER SRM 53-11-1. (M)