What was found
CLT - DURING C-4 CHECK VISUAL INSPECTION, FOUND A 2 INCH BY 4 INCH AREA OF CORROSION AT STATION 346 FLOORBEAM. INSTALLED REPAIR ANGLE PER EA 64434. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING C-4 CHECK VISUAL INSPECTION, FOUND A 2 INCH BY 4 INCH AREA OF CORROSION AT STATION 346 FLOORBEAM. INSTALLED REPAIR ANGLE PER EA 64434. (M)