What was found
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 2 INCH AREA OF CORROSION AT TERMINAL END STRINGER 26R AT STATION 540. INSTALLED NEW END FITTING PER SRM 51-10-01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 2 INCH AREA OF CORROSION AT TERMINAL END STRINGER 26R AT STATION 540. INSTALLED NEW END FITTING PER SRM 51-10-01. (M)