What was found
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 2 INCH BY 67 INCH AREA OF SPOTTED CORROSION AT RBL 20 STATION 780-847 STRAP. INSTALLED NEW STRAP PER SRM 51-10-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 2 INCH BY 67 INCH AREA OF SPOTTED CORROSION AT RBL 20 STATION 780-847 STRAP. INSTALLED NEW STRAP PER SRM 51-10-02. (M)