What was found
TPA - DURING UNSCHEDULED MAINTENANCE, FOUND .125 INCH CRACK IN SKIN AT STATION 947 AND STRINGER 14R. INSTALLED DOUBLER MADE OF .063 INCH STAINLESS STEEL .5 HARD PER SRM 53-30-3 FIG 21A. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TPA - DURING UNSCHEDULED MAINTENANCE, FOUND .125 INCH CRACK IN SKIN AT STATION 947 AND STRINGER 14R. INSTALLED DOUBLER MADE OF .063 INCH STAINLESS STEEL .5 HARD PER SRM 53-30-3 FIG 21A. (M)