CLT - DURING Q-2 CHECK, FOUND 1 INCH BY 1 INCH CORRODED AREA ON FLOORBEAM AT BS 312 RBL 37, WL 208.1. CORROSION LEVEL 2. CORROSION TASK NR C53-107-02. CUT OUT DAMAGE AND INSTALLED FILLER AND DOUBLER PER SRM 53-10-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-2 CHECK, FOUND 1 INCH BY 1 INCH CORRODED AREA ON FLOORBEAM AT BS 312 RBL 37, WL 208.1. CORROSION LEVEL 2. CORROSION TASK NR C53-107-02. CUT OUT DAMAGE AND INSTALLED FILLER AND DOUBLER PER SRM 53-10-51. (M)