What was found
CLT - DURING C-4 CHECK, FOUND 3 INCH CORRODED AREAS AROUND NUTPLATE HOLES AT T-CAP FRAME AT STATION 287 RBL 63, CORROSION LEVEL 2. REPAIRED T-CAP PER SRM 53-00-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING C-4 CHECK, FOUND 3 INCH CORRODED AREAS AROUND NUTPLATE HOLES AT T-CAP FRAME AT STATION 287 RBL 63, CORROSION LEVEL 2. REPAIRED T-CAP PER SRM 53-00-51. (M)