What was found
CLT - DURING C-4 CHECK, FOUND 2 INCH CORRODED AREA OF FLOORBEAM AT STATION 287 RBL 79. CORROSION LEVEL 1. SPLICED SECTION T-CAP, INSTALLED REPAIR ANGLES EPR SRM 51-10. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING C-4 CHECK, FOUND 2 INCH CORRODED AREA OF FLOORBEAM AT STATION 287 RBL 79. CORROSION LEVEL 1. SPLICED SECTION T-CAP, INSTALLED REPAIR ANGLES EPR SRM 51-10. (M)