What was found
PIT - DURING Q-4 CHECK, FOUND CORROSION THE WHOLE WAY THROUGH END CAP, AT STATION 996 - LONGERON 19R. CORROSION LEVEL 1. CORROSION TASK NR C-57-53300. REWORKED AND REPLACED END CAP FITTING. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.