CLT - DURING Q-2 CHECK, FOUND .75 INCH CRACK IN FUSELAGE FRAME AT FASTENER HOLE AT BS 827, BETWEEN STRINGER 8R/9R. INSTALLED DOUBLER PER SRM 53-00-07. (M)