What was found
CLT - DURING Q4 CHECK, FOUND PREVIOUS BLEND OUT TOP OF T-CAP ON BEAM AT STATION 328 LBL 49, WL 208. INSTALLED REPAIR DOUBLERS AND SPLICE OT CAP PER SRM 53-10-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q4 CHECK, FOUND PREVIOUS BLEND OUT TOP OF T-CAP ON BEAM AT STATION 328 LBL 49, WL 208. INSTALLED REPAIR DOUBLERS AND SPLICE OT CAP PER SRM 53-10-51. (M)