What was found
CLT - DURING Q4 CHECK, FOUND 2 INCH DIAMETER CORRODED AREA AT AFT OUTBOARD LAV MOUNT AT STATION 1012, RBL 37, FLOOR LEVEL. CORROSION LEVEL 1, CORROSION TASK NR C53-107-02. REPLACED SUPPORT MOUNT PER SRM 51-10-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q4 CHECK, FOUND 2 INCH DIAMETER CORRODED AREA AT AFT OUTBOARD LAV MOUNT AT STATION 1012, RBL 37, FLOOR LEVEL. CORROSION LEVEL 1, CORROSION TASK NR C53-107-02. REPLACED SUPPORT MOUNT PER SRM 51-10-02. (M)