CLT - DURING Q-1 CHECK, FOUND .12 5INCH CRACK IN TIE CLIP AT STATION 727C STRINGER 6L. DEFECTIVE PART REPLACED WITH IDENTICAL PART NR PER SRM 51-10-02. (M)