What was found
CLT - DURING Q-1 CHECK, FOUND 1.5 INCH CRACK AND .400 INCH CRACK JUST AFT OF STATION 663.75 BL 32 IN PRESSURE FLOOR PANEL. INSTALLED DOUBLER, FILLER AND ANGLE STIFFENER PER EA 64667. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-1 CHECK, FOUND 1.5 INCH CRACK AND .400 INCH CRACK JUST AFT OF STATION 663.75 BL 32 IN PRESSURE FLOOR PANEL. INSTALLED DOUBLER, FILLER AND ANGLE STIFFENER PER EA 64667. (M)