What was found
CLT - DURIGN Q-4 CHECK VISUAL INSPECTION, FOUND A .25 INCH CRACK AROUND RIVET AT BS 867 BETWEEN STRINGER 8R AND 9R FRAME. INSTALLED REPAIRE ANGLE PER EA 64815. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURIGN Q-4 CHECK VISUAL INSPECTION, FOUND A .25 INCH CRACK AROUND RIVET AT BS 867 BETWEEN STRINGER 8R AND 9R FRAME. INSTALLED REPAIRE ANGLE PER EA 64815. (M)