CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND A .25 INCH CRACK AT BS 480 BETWEEN STR 8 AND STR 9L IN FUSELAGE FRAME AT FASTENER HOLE. INSTALLED DOUBLER. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND A .25 INCH CRACK AT BS 480 BETWEEN STR 8 AND STR 9L IN FUSELAGE FRAME AT FASTENER HOLE. INSTALLED DOUBLER. (X)