CLT - DURING C-1 CHECK VISUAL INSPECTION, FOUND A 1 INCH BY 2.25 INCH AREA OF CORROSION AT STATION 1330 LBL 29 BETWEEN STRINGER 27L AND 28L SKIN, CORROSION LEVEL 2. INTERIM REPAIR (DOUBLER) PER EA 65029 AND SRM 53-00-01 FIG 204. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING C-1 CHECK VISUAL INSPECTION, FOUND A 1 INCH BY 2.25 INCH AREA OF CORROSION AT STATION 1330 LBL 29 BETWEEN STRINGER 27L AND 28L SKIN, CORROSION LEVEL 2. INTERIM REPAIR (DOUBLER) PER EA 65029 AND SRM 53-00-01 FIG 204. (M)