What was found
CLT - DURING A Q-1 CHECK VISUAL INSPECTION, FOUND A .25 INCH CRACK AT BS 616 STR 1 TIE CLIP. INSTALLED NEW CLIP PER SRM 51-10-02. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING A Q-1 CHECK VISUAL INSPECTION, FOUND A .25 INCH CRACK AT BS 616 STR 1 TIE CLIP. INSTALLED NEW CLIP PER SRM 51-10-02. (X)