As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CLT - DURING A Q-1 CHECK VISUAL INSPECTION, FOUND CORRODED AREA VARIOUS SIZES AND PLACES ON Z-ANGLE/GIRT BAR MOUNTS FORWARD ENTRY DOOR AT BS 312 TO BS 344. INSTALLED NEW Z-ANGLE AND GIRT BAR MOUNTS PER SRM 51-40-02 AND SRM 53-10-15. (X)