What was found
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A .500 INCH CRACK MAIN ENTRY DOORWAY UPPER HINGE H-STRAP DOORWAY FRAME. FABRICATED AND INSTALLED NEW H-STRAP PER SRM 51-10-02 AND BOEING DWG 90-7822. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A .500 INCH CRACK MAIN ENTRY DOORWAY UPPER HINGE H-STRAP DOORWAY FRAME. FABRICATED AND INSTALLED NEW H-STRAP PER SRM 51-10-02 AND BOEING DWG 90-7822. (X)