What was found
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A .50 INCH CRACK FRAME 312 AT STR 5L. CRACK TRIMMED OUT AND DOUBLER INSTALLED PER SRM 53-00-07 FIG 202 AND EA 65075. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A .50 INCH CRACK FRAME 312 AT STR 5L. CRACK TRIMMED OUT AND DOUBLER INSTALLED PER SRM 53-00-07 FIG 202 AND EA 65075. (X)