What was found
TPA - DURING RON, FOUND 8 SQUARE INCH OF CORROSION ON FLOORBEAM AT STATION 1016 AND BL 0. SPLICED NEW SECTION OF BEAM PER SRM 53-10-9 FIG 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TPA - DURING RON, FOUND 8 SQUARE INCH OF CORROSION ON FLOORBEAM AT STATION 1016 AND BL 0. SPLICED NEW SECTION OF BEAM PER SRM 53-10-9 FIG 2. (M)