What was found
PIT - DURING RON MAINTENANCE, FOUND 5 INCH LONG CRACK AT STATION 420, BODY LINE 0, CENTER LINE UNDERSIDE ON FUSELAGE SKIN. INSTALLED EXTERNAL DOUBLER PER SRM 53-30-3 FIG 1 (SHEET 4). (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING RON MAINTENANCE, FOUND 5 INCH LONG CRACK AT STATION 420, BODY LINE 0, CENTER LINE UNDERSIDE ON FUSELAGE SKIN. INSTALLED EXTERNAL DOUBLER PER SRM 53-30-3 FIG 1 (SHEET 4). (M)