What was found
CLT - DURING C-4 CHECK VISUAL INSPECTION, FOUND A .75 INCH BY .75 INCH AREA OF CORROSION AT STATION 377, LBL 43 AROUND SCREW HOLES ON FLOORBEAM, CORROSION LEVEL 2. INSTALLED DOUBLER REPAIR ANGLE PER TR 53-15-02 AND SRM 51-10-00. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING C-4 CHECK VISUAL INSPECTION, FOUND A .75 INCH BY .75 INCH AREA OF CORROSION AT STATION 377, LBL 43 AROUND SCREW HOLES ON FLOORBEAM, CORROSION LEVEL 2. INSTALLED DOUBLER REPAIR ANGLE PER TR 53-15-02 AND SRM 51-10-00. (M)