What was found
CLT - DURING Q-3 CHECK, FOUND CORROSION ON UPPER SURFACE OF FLOORBEAM T-CAP AT STATION 947 BETWEEN LBL 14 TO RBL 16, CORROSION LEVEL 2. CORROSION TASK NR C53-107-02. SPLICED T-CAP SECTION/DOUBLERS PER SRM 53-00-51 FIG 202. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-3 CHECK, FOUND CORROSION ON UPPER SURFACE OF FLOORBEAM T-CAP AT STATION 947 BETWEEN LBL 14 TO RBL 16, CORROSION LEVEL 2. CORROSION TASK NR C53-107-02. SPLICED T-CAP SECTION/DOUBLERS PER SRM 53-00-51 FIG 202. (M)