What was found
CLT - DURING Q3 CHECK, FOUND TIE CLIP CRACKED IN HALF. ALSO, FOUND STRINGER CRACKED BELOW CLIP LOCATION, STATION 616, S-4L. INSTALLED STRINGER DOUBLER PER SRM 53-00-03 FIG 204 AND FABRICATED TIE CLIP AND INSTALLED PER SRM 51-10-1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q3 CHECK, FOUND TIE CLIP CRACKED IN HALF. ALSO, FOUND STRINGER CRACKED BELOW CLIP LOCATION, STATION 616, S-4L. INSTALLED STRINGER DOUBLER PER SRM 53-00-03 FIG 204 AND FABRICATED TIE CLIP AND INSTALLED PER SRM 51-10-1. (M)