What was found
CLT - DURING Q3 CHECK, FOUND 1 INCH CRACK AT CREASE BEAM INNER CHORD ANGLE BS 294.5 RBL 45 WL 208. INSTALLED CHORD ANGLE PER SRM 51-10-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q3 CHECK, FOUND 1 INCH CRACK AT CREASE BEAM INNER CHORD ANGLE BS 294.5 RBL 45 WL 208. INSTALLED CHORD ANGLE PER SRM 51-10-02. (M)