What was found
CLT - DURING Q-1 CHECK VISUAL AND EDDY CURENT INSPECTION, FOUND A 1 INCH CRACK AT BS 178, WL 195, RBL 25, AFT SIDE PRESSURE BULKHEAD INTERCOSTAL. INSTALLED ACCESS COVER PER SRM 53-10-08. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-1 CHECK VISUAL AND EDDY CURENT INSPECTION, FOUND A 1 INCH CRACK AT BS 178, WL 195, RBL 25, AFT SIDE PRESSURE BULKHEAD INTERCOSTAL. INSTALLED ACCESS COVER PER SRM 53-10-08. (X)