What was found
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A ..125 INCH CRACK STATION 907 STRINGER 9L OVERHEAD BIN ATTACH POINT FRAME. INSTALLED REPAIRED ANGLE PER EA 65193. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A ..125 INCH CRACK STATION 907 STRINGER 9L OVERHEAD BIN ATTACH POINT FRAME. INSTALLED REPAIRED ANGLE PER EA 65193. (M)