What was found
CLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND A .25 INCH CRACK STATION 639 STRINGER 5L TIE CLIP. INSTALLED NEW TIE CLIP PER SRM 51-40-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND A .25 INCH CRACK STATION 639 STRINGER 5L TIE CLIP. INSTALLED NEW TIE CLIP PER SRM 51-40-02. (M)