What was found
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 2 INCH BY 2 INCH AREA OF CORROSION AT STATION 360, RBL 12 FLOORBEAM. CORROSION LEVEL 1. REPAIRED ANGLES PER SRM 53-00-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 2 INCH BY 2 INCH AREA OF CORROSION AT STATION 360, RBL 12 FLOORBEAM. CORROSION LEVEL 1. REPAIRED ANGLES PER SRM 53-00-51. (M)