What was found
CLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND A CRACKED CLIP STATION 663.75 AT STRINGER 10R. REPLACED CLP PER SRM 51-10-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND A CRACKED CLIP STATION 663.75 AT STRINGER 10R. REPLACED CLP PER SRM 51-10-02. (M)