What was found
CLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND A 1 INCH BY 1 INCH AREA OF CORROSION LBL 21, 28, 35, 42 AND 45, BS 344, WL 208.1 FLOORBEAM. CORROSION LEVEL 1. INSTALLED NEW SECTION OF T-CAP WITH REPAIR ANGLES PER SRM 53-10-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND A 1 INCH BY 1 INCH AREA OF CORROSION LBL 21, 28, 35, 42 AND 45, BS 344, WL 208.1 FLOORBEAM. CORROSION LEVEL 1. INSTALLED NEW SECTION OF T-CAP WITH REPAIR ANGLES PER SRM 53-10-51. (M)