CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 1 INCH BY 3 INCH AREA OF CORROSION BS 1007, STRINGER 23R, CORROSION LEVEL 1. INSTALLED STRINGER SPLICE PER SRM 53-00-03. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 1 INCH BY 3 INCH AREA OF CORROSION BS 1007, STRINGER 23R, CORROSION LEVEL 1. INSTALLED STRINGER SPLICE PER SRM 53-00-03. (M)