CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A ..125 INCH CRACK STATION 807 FRAME, STRINGER 9R OVERHEAD BIN ATTACH POINT. INSTALLED REPAIR ANGLE AND FILLER PER EA 65193 AND SRM 53-00-07 FIG 202. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A ..125 INCH CRACK STATION 807 FRAME, STRINGER 9R OVERHEAD BIN ATTACH POINT. INSTALLED REPAIR ANGLE AND FILLER PER EA 65193 AND SRM 53-00-07 FIG 202. (M)