CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A ..25 INCH CRACK STATION 907 PLUS 1/2 AT STRINGER 4L. INSTALLED NEW STRINGER SPLICE PER SRM 51-10-00. (M)