CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A ..125 INCH CRACK STATION 380 BETWEEN STRINGER 8R AND 9R FRAME. INSTALLED DOUBLER PER SRM 53-30-07. (M)