What was found
PIT - DURING RON, FOUND .8750 INCH CRACK IN RADIUS OF Z-ANGLE DOOR FRAME AT R1 ABOVE BOTTOM HINGE CUT-OUT IN DOOR OPENING. STOP DRILLED CRACK, INSTALLED TITANIUM DOUBLER PER SRM 53-10-15, FIG 3, SH 2/ER 07-07-90/EA 52711. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING RON, FOUND .8750 INCH CRACK IN RADIUS OF Z-ANGLE DOOR FRAME AT R1 ABOVE BOTTOM HINGE CUT-OUT IN DOOR OPENING. STOP DRILLED CRACK, INSTALLED TITANIUM DOUBLER PER SRM 53-10-15, FIG 3, SH 2/ER 07-07-90/EA 52711. (X)