CLT - DURNG Q-2 CHECK VISUAL INSPECTION, FOUND A 2 INCH BY 1 INCH AREA OF CORROSION LEFT FACE OF BS 1016 PRESSURE BULKHEAD CTR BL 0 STIFFENER. CORROSION LEVEL 2. INSTALLED DOUBLER PER SRM 53-80-08 AND EA 65447. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURNG Q-2 CHECK VISUAL INSPECTION, FOUND A 2 INCH BY 1 INCH AREA OF CORROSION LEFT FACE OF BS 1016 PRESSURE BULKHEAD CTR BL 0 STIFFENER. CORROSION LEVEL 2. INSTALLED DOUBLER PER SRM 53-80-08 AND EA 65447. (M)