What was found
CLT - DURING C-3 CHECK VISUAL INSPECTION, FOUND A .125 INCH CRACK AT STATION 1520, STRINGER 26L TIE CLIP. REPAIRED PER SRM 53-00-07. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING C-3 CHECK VISUAL INSPECTION, FOUND A .125 INCH CRACK AT STATION 1520, STRINGER 26L TIE CLIP. REPAIRED PER SRM 53-00-07. (M)