What was found
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 1.5 INCH CRACK AT BS 327 FORWARD SERVICE DOOR CUTOUT AFT LOWER CORNER EXTERIOR SKIN. INSTALLED TRIPLER PER SRM 53-10-01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 1.5 INCH CRACK AT BS 327 FORWARD SERVICE DOOR CUTOUT AFT LOWER CORNER EXTERIOR SKIN. INSTALLED TRIPLER PER SRM 53-10-01. (M)