What was found
PIT - DURING RON, FOUND 3 VERTICAL CRACKS .5 INCH, .75 INCH, .75 INCH LEFT SIDE STATION 58.750 FORWARD RIVET LINE BETWEEN 2.5 AND 5 INCH BELOW COCKPIT FLOOR LINE. STOP DRILLED CRACKS, INSTALLED EXTERNAL DOUBLER PER SRM 53-01, FIG 2. (M)