What was found
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND CORROSION RUNNING ALONG TOP AND SECONDARY CAPS OF BEAM APPROX 1 INCH BEAM 986.5, LBL 04, CORROSION LEVEL 1. INSTALLED UPPER BEAM CAP REPAIR PER SRM 53-10-05. (M)