What was found
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND 2 INCH BY 24 INCH AREA OF CORROSION AT STATION 1016 FLOORBEAM AND INTERCOSTAL. CORROSION LEVEL 2. REPLACED INTERCOSTAL. INSTALLED REPAIR DOUBLERS AND STRAPS PER EA 65584. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND 2 INCH BY 24 INCH AREA OF CORROSION AT STATION 1016 FLOORBEAM AND INTERCOSTAL. CORROSION LEVEL 2. REPLACED INTERCOSTAL. INSTALLED REPAIR DOUBLERS AND STRAPS PER EA 65584. (M)