What was found
PIT - DURING RON FOUND 3 CRACKS 2.5 INCH BY 1 INCH LONG AT STATION 58.750 LT, LONGERON 18/19. INSTALLED DOUBLER AND FILLER PER SRM 53-01 FIG 2 SHEET 3, PAGE 9. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING RON FOUND 3 CRACKS 2.5 INCH BY 1 INCH LONG AT STATION 58.750 LT, LONGERON 18/19. INSTALLED DOUBLER AND FILLER PER SRM 53-01 FIG 2 SHEET 3, PAGE 9. (M)