What was found
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 20 INCH AREA OF CORROSION RT SERVICE DOOR Z-ANGLE BETWEEN STATION 947.5 AND 986.5. CORROSION LEVEL 1. INSTALLED NEW Z-ANGLE PER SRM 53-60-51, LIMITS AND SRM 51-10-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 20 INCH AREA OF CORROSION RT SERVICE DOOR Z-ANGLE BETWEEN STATION 947.5 AND 986.5. CORROSION LEVEL 1. INSTALLED NEW Z-ANGLE PER SRM 53-60-51, LIMITS AND SRM 51-10-02. (M)