What was found
CLT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND A .3750 INCH CRACK AT BS 907, STR 9L STRINGER TIE CLIP. REPAIRED WITH IDENTICAL PART PER SRM 51-10-2. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND A .3750 INCH CRACK AT BS 907, STR 9L STRINGER TIE CLIP. REPAIRED WITH IDENTICAL PART PER SRM 51-10-2. (X)