What was found
PIT - DURING RON, FOUND 1 INCH CRACK IN SKIN WITH EXTERNAL DOUBLER WITHIN 24 INCHES OF AOA VANE AT STATION 58.750, 4 INCHES BELOW FLOOR LINE LEFT SIDE. INSTALLED FLUSH REPAIR PER SRM 53-01 FIG 4 SHT 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING RON, FOUND 1 INCH CRACK IN SKIN WITH EXTERNAL DOUBLER WITHIN 24 INCHES OF AOA VANE AT STATION 58.750, 4 INCHES BELOW FLOOR LINE LEFT SIDE. INSTALLED FLUSH REPAIR PER SRM 53-01 FIG 4 SHT 2. (M)