What was found
CLT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND A .125 INCH CRACK AT STATION 400 BETWEEN STRINGER 8R AND STRINGER 9R FRAME. INSTALLED DOUBLER PER SRM 53-00-07 AND EA 65705. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND A .125 INCH CRACK AT STATION 400 BETWEEN STRINGER 8R AND STRINGER 9R FRAME. INSTALLED DOUBLER PER SRM 53-00-07 AND EA 65705. (M)