What was found
CLT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND CORROSION 1 INCH BY 1 INCH AT STATION 294, RBL 12 BEAM. CORROSION LEVEL 2. CORROSION TASK NR C53-107-02. INSTALLED NEW SECTION OF T-CAP WITH REPAIR SPLICES PER SRM 53-10-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND CORROSION 1 INCH BY 1 INCH AT STATION 294, RBL 12 BEAM. CORROSION LEVEL 2. CORROSION TASK NR C53-107-02. INSTALLED NEW SECTION OF T-CAP WITH REPAIR SPLICES PER SRM 53-10-51. (M)